डिजिटल मल्टीमीटर मरम्मत युक्तियाँ

Apr 07, 2022

डिजिटल मल्टीमीटर मरम्मत युक्तियाँ

एक दोषपूर्ण उपकरण के लिए, पहले जांच करें और निर्धारित करें कि क्या गलती की घटना सामान्य है (सभी कार्यों को मापा नहीं जा सकता है) या व्यक्तिगत (व्यक्तिगत कार्य या व्यक्तिगत श्रेणियां), और फिर स्थिति को अलग करें और इसे लक्षणात्मक रूप से हल करें।

⒈ If all gears cannot work, focus on checking the power supply circuit and A/D converter circuit. When checking the power supply part, you can remove the laminated battery, press the power switch, connect the positive test lead to the negative power supply of the meter under test, and connect the negative test lead to the positive power supply (for digital multimeters), switch the switch to the diode measurement gear, if the display shows If it is the forward voltage of the diode, it means that the power supply part is good. If the deviation is large, it means that there is a problem with the power supply part. If there is an open circuit, focus on checking the power switch and battery leads. If there is a short circuit, you need to use the circuit breaking method to gradually disconnect the components that use the power supply, focusing on checking operational amplifiers, timers, and A/D converters. If a short circuit occurs, more than one integrated component is generally damaged. The A/D converter can be checked at the same time as the basic meter, which is equivalent to the DC meter of an analog multimeter. The specific inspection method is as follows:

⑴The range of the meter under test is turned to the lowest level of DC voltage;

(2) मापें कि क्या ए / डी कनवर्टर का कार्यशील वोल्टेज सामान्य है। तालिका में प्रयुक्त ए/डी कनवर्टर मॉडल के अनुसार, वी प्लस पिन और कॉम पिन के अनुरूप, मापा मूल्य की तुलना उसके विशिष्ट मूल्य से करें।

(3) ए / डी कनवर्टर के संदर्भ वोल्टेज को मापें। आमतौर पर इस्तेमाल होने वाले डिजिटल मल्टीमीटर का रेफरेंस वोल्टेज आमतौर पर 100mV या 1V होता है, यानी VREF plus और COM के बीच DC वोल्टेज को मापा जाता है। यदि यह 100mV या 1V से विचलित होता है, तो इसे बाहरी पोटेंशियोमीटर द्वारा समायोजित किया जा सकता है।

⑷ Check the displayed number of input zero, short{{0}}circuit the positive terminal IN plus of the A/D converter with the negative terminal IN-, make the input voltage Vin=0, and the meter displays "00.0" or "00.00".

⑸ Check the full bright stroke of the display. Short-circuit the test terminal TEST pin with the positive power supply terminal V plus to make the logic ground become a high potential, and all digital circuits stop working. Because DC voltage is applied to each stroke, all strokes are bright and the alignment table displays "1888", and the alignment table displays "18888". If there is a missing stroke, check the corresponding output pin of the A/D converter and the conductive glue (or connection), and check whether there is poor contact and disconnection between the A/D converter and the display.

⒉ If there is a problem with individual files, it means that the A/D converter and the power supply part are working normally. Because DC voltage and resistance files share a set of voltage divider resistors; AC and DC current share a shunt; AC voltage and AC current share a set of AC/DC converters; others such as Cx, HFE, F, etc. are composed of independent different converters . Understand the relationship between them, and then according to the power diagram, it is easy to find the fault location. If the measurement of the small signal is inaccurate or the displayed number jumps greatly, focus on checking whether the contact of the range switch is good.

3. If the measured data is unstable, and the value always increases cumulatively, the input terminal of the A/D converter is short-circuited, and the displayed data is not zero, which is generally caused by the poor performance of the 0.1μF reference capacitor.

According to the above analysis, the basic sequence of repairing the digital multimeter should be: digital meter head→DC voltage→DC current→AC voltage→AC current→resistance gear (including buzzer and checking diode positive voltage drop)→Cx→HFE , F, H, T, etc. But it should not be too mechanical. Some obvious problems can be dealt with first. But when making adjustments, be sure to follow the above procedure.

संक्षेप में, एक दोषपूर्ण मल्टीमीटर, उचित परीक्षण के बाद, पहले गलती के संभावित हिस्सों का विश्लेषण करना चाहिए, और फिर प्रतिस्थापन और मरम्मत के लिए सर्किट आरेख के अनुसार गलती स्थान का पता लगाना चाहिए। क्योंकि डिजिटल मल्टीमीटर एक अपेक्षाकृत सटीक उपकरण है, प्रतिस्थापन घटकों को समान मापदंडों वाले घटकों द्वारा प्रतिस्थापित किया जाना चाहिए, विशेष रूप से ए / डी कनवर्टर के प्रतिस्थापन, एकीकृत ब्लॉक का उपयोग करना चाहिए जिसे निर्माता द्वारा सख्ती से जांचा गया है, अन्यथा वहाँ होगा त्रुटियां होंगी और आवश्यकताओं को पूरा नहीं करेंगी। शुद्धता। नए बदले गए A/D कनवर्टर को भी ऊपर वर्णित विधि के अनुसार जाँचने की आवश्यकता है, और नए के कारण उस पर भरोसा नहीं किया जाना चाहिए।


2